Test Code TS Type and Screen
Specimen Information
Obtain specimen using standard phlebotomy techniques.
No special patient preparation is necessary.
Container | Specimen | Temperature | Collect Vol | Submit Vol | Min Vol | Stability |
Pink Top | Whole Blood | Refrigerate | 4 mL | 4 mL | 4 mL | 7 Days |
Red Top | Whole Blood | Refrigerate | 4 mL | 4 mL | 4 mL | 7 Days |
Pink top tube preferred, however, a plain red top is also acceptable.
Serum gel tubes are not acceptable for testing.
Specimems must be labeled with the patient's full legal name (no nick-names), date of birth, date and time of collection, and an identifier of the collector (initials or employee ID number).
Reject Due To:
- Hemolysis
- Specimen unlabeled or mislabeled
Instrumentation / Method
Manual / Agglutination by test tube
Test Schedule / Analytical Time / Test Priority
Daily / Same Day / Available STAT
Reference Range
Negative for antibodies
CPT / LOINC
CPT:
ABO: 86900
Rh: 86901
Antibody Screen: 86850
LOINC: