Test Code HPVSELF SELF-COLLECT HPV DNA DETECTION WITH GENOTYPING, PCR, VAGINAL
Additional Codes
LAB17722
Specimen Information
| Container | Specimen | Temperature | Collect Vol | Submit Vol | Min Vol | Stability |
| ThinPrep Vial | Vaginal | Ambient | 20 mL | 20 mL | 20 mL | 30 days |
Collection of self-collected specimen
Self collection instructions for Copan FLOQSwabs (552C.RM)
The FLOQSwabs is to be used for the collection of vaginal specimens for HPV. Users should read and carefully follow instructions.
Open the swab just before use and be careful not to touch any surfaces with the swab tip.
Do NOT Use:
- during pregnancy or in the 3 months after giving birth
- if recently undergone gynecological surgery
- in case of unusual bleeding or pelvic pain
Test Schedule / Analytical Time / Test Priority
Monday – Friday / 1 day / Not available STAT
Method
RT-PCR
Instrumentation
Roche Cobas 6800
Reference Range
Negative for HPV. No DNA detected from HPV types 16,18, 31, 33, 35, 39, 45, 51, 52, 56, 58, 59, 66, and 68.
Section
Chemistry
Performing Location
University of Vermont Medical Center
Is the UVMMC lab NY State Certified to perform this testing? Yes/No
Yes
CPT Code(s)
| Description | CPT Code |
| HPV Detection, High Risk Types | 87626 |
Result Interpretations and Follow-up
| Results | Follow-up |
| Negative HPV | Repeat testing in 3 years |
| Positive HPV (other high-risk genotypes) | Return for provider-collected Pap |
| Positive HPV (types 16/18) | Refer to colposcopy |
Sample Suspension Instructions
Self-collected sample must be placed into medium after sample has been collected.
- Read all instructions before starting sample suspension.
- For sample collection, follow the collection device manufacturer's Instructions for use.
- Once the sample has been collected, continue with the following instructions to preserve the sample: